Saturday, June 30, 2018

General info-08

Guard columns

In HPLC, Guard columns are mostly used to extend the life of the analytical columns. Guard column is a small sized column packed with the same packing material as like analytical column. Since the frits on guard column also remains same as those on analytical column, the particles blocking the analytical column will block the guard column first. So the analytical column will be safeguarded by the use of guard columns.
(Analytical columns- Columns like IEX, RPC, SEC, HIC normally used for the purification and analysis of samples)

Friday, June 29, 2018

RPC-04

Use of Ion Pairing reagents in RPC

Ion pairing reagents are mainly used in RPC to make the analytes to interact with stationary phase (refer previous RPC posts). Ion pairing reagents will bind to the ionic molecules in the analyte via ionic interactions which make the hydrophobic groups present in the analyte to be exposed out for the affinity of binding with stationary phase. Trifluoroacetic acid is mostly used as an ion pairing reagent for the reversed phase separation of peptides (Glajch J L et al, 1987) (Shibue M et al, 2005). Here, the negatively charged trifluoroacetate interacts with the positively charged amino acid residues and makes the analyte less hydrophilic. (Geraldine Thevenon, 1989) 


Thursday, June 28, 2018

IEX-03

Effect of Isoelectric point on IEX

Every protein has an Isoelectric point (pI) (refer General info-01). When a protein is at its pI the protein will not even bind to the ion-exchange resin. Below this pH the protein will have a net positive charge and will bind to a cation exchanger, and above this pH it will have a net negative charge and bind to an anion exchanger. 

IEX-02

Stationary phase in IEX

The cation exchanger has sulfomethyl, carboxymethyl groups and the anion exchanger has Quarternary ammonium, Diethylaminoethyl (DEAE) groups attached to the stationary phase resin. 

Wednesday, June 27, 2018

IEX-01

Ion Exchange Chromatography (IEX) 

Ion exchange chromatography (IEX) separates proteins based on their net surface charge, through electrostatic interactions that occur between proteins and a charged stationary phase.

Types of IEX 
Two types of IEX exist:
1) Anion exchange (Negatively charged proteins bind to positively charged stationary phase)
2) Cation exchange (Positively charged proteins bind to negatively charged stationary phase)
Image designed by Tutkia biotech

Sunday, June 24, 2018

General info-07

Know about Ghost peaks 

One of the major problems in chromatography is the occurrence of ghost peaks in chromatogram. These peaks are mainly due to the contamination of column from previous run samples. So to avoid those ghost peaks, the column should be washed or flushed  properly with strong solvents at the end of every runs.

RPC-03

Endcapping

During manufacture of RP columns, some of the silanol groups remain on the surface of the silica after immobilization of non polar functional groups. This is because of the steric hindrance from C8 or C18 chains. Basically the stationary phase of  RPC should be non polar but the silanol groups are polar. This leads to the chance of interaction of unwanted analytes with stationary phase resulting in poor peak resolution and peak tailing. End capping is used to mask this interaction by replacing silanol groups with trimethylsilyl group.The reagents like trimethylchlorosilane and dichlorodimethylsilane are commonly used for end capping the reverse phase columns. 

Thursday, June 21, 2018

General info-06

Modes of elution

Isocratic elution - The mobile phase composition remains the same throughout the run time. 
Example: Don't think only 100%  of  mobile phase A or B is Isocratic mode. If the run time is 8 minutes, either the mobile phase of 100% or  composition of A-80% + B-20%  runs same for 8 minutes in this mode.

Gradient elution - The mobile phase composition changes during the run time. 
Example: If the run time is same 8 minutes, the mobile phase composition of A-80% + B-20% runs for first 4 minutes and it changes to A-60% + B-40% for next 4 minutes in gradient mode.

Wednesday, June 20, 2018

RPC-02

Stationary phase in RPC

The stationary phase of RPC is non polar/hydrophobic (refer previous post RPC-01).The hydrophobic nature is achieved by the alkyl chains (C18, C8 and C4), amide, phenyl or cyano groups bonded to the stationary support silica. Order of increase in Hydrophobicity is C4<C8<C18. This statement shows C18 is more hydrophobic than C8 and C4 because 18 (CH3) alkyl groups are bounded to the silica support.

Tuesday, June 19, 2018

General info-05

Know about Transposons

Transposons are the genes having the ability to jump either from one piece of DNA to another or other position of the same DNA. These start to emerge when a gene is bounded by insertion sequences on both sides. This causes mutations when they jump to the middle of the gene. These are more resistant to antibiotics. (Bioprocess engineering Michael L. Shuler)

RPC-01

Reverse Phase Chromatography (RPC)

Reverse Phase chromatography separates molecules based on the differences in hydrophobicity of molecules. RPC uses hydrophobic stationary phase. The hydrophobic nature is achieved by the non polar functional groups bonded to the stationary phase. The mobile phase in RPC is polar. The non-polar compounds bind to the stationary phase by hydrophobic interaction. Then the bonded analytes are eluted from the column by using non-polar solvents.(Mant C T, 1996)(Jason Olbrich, 2013)


Principle of Reverse Phase Chromatography
Image designed by tutkiabiotech

Sunday, June 17, 2018

Link-01

Reference books for Chromatographic techniques

Students interested in purification and chromatography can use the below links to gain more knowledge in different chromatographic techniques.

Introduction to Modern Liquid Chromatography - Important book

Reverse Phase & Hydrophobic Interaction Chromatography
Ion Exchange Chromatography
Size Exclusion Chromatography

Higher studies-01

Competitive exams after B.Tech BT

 Students who are more passionate about doing masters degree after B.Tech Biotechnology have the dream to enter into good institutes. Most of them know only about GATE. The following are the few competitive exams after B.Tech:
 
                   1. GATE 

                   2. TIFR

                   3. DBT  

                   4. CSIR UGC NET

                   5. JNU

                   6. TANCET

                   7. GRE  (for abroad)
                   
                   8. IELTS  (for abroad)
                   
                   9. TOFEL (for abroad)

Tb info-02

Resume Building

The students stepped into final year are now at the stage of making decisions about their career. Some plan for higher studies and some would like to be a part of  any core companies. The first step for that is to build a good resume. In Interview, most of the questions will be raised from the resume. So be aware of the contents what you are adding in the resume. Even your resume will sometimes impress the recruiters among other candidates.

 For this week, Tb comes to help you in resume building. Kindly make use of this and feel free to drop your doubts in our contact form. 

Biotech Companies in Bangalore

Don't think there is no scope in Biotechnology. There are ocean full of companies as like IT  to make your dreams come true. See the list of biotech companies only in Bangalore area. Visit those websites for the career opportunities and make your life to shine in Biotech... 

Anthem Biosciences
www.anthembio.com

Accelrys Inc

Advanta India Ltd

Azyme Biosciences Private Limited

Avestha Gengraine Technologies Pvt Ltd

Alfa Laval India Ltd

Alltech

Aurigene Discovery Technologies Limited

AstraZeneca India Pvt Ltd

Bangalore Genei Pvt Ltd

Bigtec Labs  Pvt Ltd
www.bigteclabs.com

Bhat Biotech India Pvt Ltd

Biocon Limited

Biozeen

Clinigene International Pvt Ltd

Creative Biolabs 

Clintec International 

CytoGenomics (P) Ltd

EID Parry (India) Ltd

GE Healthcare Life Sciences
www.gelifesciences.com

Genotypic Technology Pvt Ltd

Glaxo SmithKline 
Greenearth Biotechnologies Ltd

Gangagen Biotechnologies Pvt Ltd

Indo-American Hybrid Seeds (India) Pvt Ltd

Jubilant Biosys (P) Ltd
Icon Clinical Research

Khoday Biotek-Palm Grove Nurseries

Kewaunee scientific corporation
www.kewaunee.com

Keygene
www.keygene.com

Lifeguard Laboratories

Lotus Labs

Millipore India Ltd

Mylan Pharmaceuticals Pvt Ltd

Metahelix Life Sciences Pvt Ltd

Micro Labs Ltd
 www.microlabsltd.com

Monsanto India Ltd

Multiplex Bio-Tech Pvt Ltd

Molecular connections

Merck Life Science Pvt Ltd
www.merck.co.in
     
Natural Remedies Pvt Ltd

Novonordisk  India Limited
www.novonordisk.co.in

Novozymes 
www.novozymes.com

Namdhari Seeds

Ontop pharmaceuticals Pvt Ltd
www.ontoppharma.com

Parry Neutraceuticals Ltd

Phalada Agro Research Foundations Pvt Ltd
     
Rallis Research Centre

Richcore Lifesciences

Sartorius India Pvt Ltd

Sun Pharmaceutical Industries Ltd

Sami Labs Ltd

Stelis Biopharma Pvt Ltd

Strand Life Sciences

Syngene International (P) Ltd
Vittal Mallya Scientific Research Foundation
Wexford laboratories

Wipro BioMed

XCyton Diagnostics
www.xcyton.com

Saturday, June 16, 2018

SEC-03

Advantages of SEC

Gel filtration can be used to remove salts from the sample, due to its ability to separate small components from the larger ones.

Mechanism: Low molecular weight salts and other compounds are removed from non-ionic and high molecular weight compounds.

General Info-04

Why do proteins detect at 280 nm?

The main reason is because of the presence of amino acids with aromatic ring structure. Example of aromatic amino acids are Tyrosine, Tryptophan and Phenylalanine.


Friday, June 15, 2018

General Info-03

Why caffeine is mostly used for calibration of UV detectors in HPLC?

Caffeine gives response at two maximas: one at 203 nm, second at 273 nm & one minima at 245nm.

Since Methyl, Ethyl & Propyl Paraben  absorbs at two maximas and one minima, It is also used as a standard for calibration of UV detectors.

SEC-02

Exclusion Limit

The upper limit of molecular weight or size beyond which molecules will elute at the same retention volume.

Retention Volume
    Retention Volume is directly proportional to the retention time at constant flow rate
  Example:  If the retention is 8 minutes and flow rate is 1 ml/min, then the retention volume is 8 ml. 

Thursday, June 14, 2018

General Info-02

Know about Unit of Pressure and Use of BET method

Unit of Pressure
  • Bar- A unit of pressure equal to one atmosphere
  • It is equivalent to 14.5 pounds per square inch (psi) or 0.1 Megapascal.

BET Method
  • A method developed by Bruner, Emmett and Teller for measuring surface area.
  • The level of liquid nitrogen adsorption within the pores of the phase is measured at very low temperatures. 
  • Pore volume and pore size distribution methods can also be obtained by this method.


SEC-01

Size Exclusion Chromatography (SEC)

  • Used mainly to separate high molecular weight samples and to determine their molecular weight distribution by virtue of their size in solution. 
  • Also known as gel permeation, gel filtration or steric exclusion chromatography.
  • Stationary phase is made of beads with pores of defined diameter. 
  • Very large molecules can’t enter into the pores and so elute first, Medium sized molecule enter with difficulties and so elute second. Small molecules enter all pores  and elute as last.
Principle of SEC
Image designed by tutkiabiotech


Wednesday, June 13, 2018

General Info-01


Know about Isoelectric Point or Isoionic point (pI)

One of the  most probable Interview questions in many pharma industries
  •  The pH point at which protein no longer has a net charge. This doesn't mean that the molecule has no charge. It has charge  i.e., all the charges are neutralized.
  •  we can also say pI is the pH at which the amino acid does not migrate in an electric field
  • Ion exchange chromatography works mostly based on pI of the protein to be separated.


HPLC-15

Column efficiency Column efficiency is the ability of the column to produce the good resolution and narrow peaks. Factors affecting Col...